loadwatch — Tier-0 NILM dataset builder

Non-intrusive load monitoring, working from a single Dutch DSMR-5 P1 stream at 1 Hz. Goal: build a labelled dataset of large-load switching events, so a model can later identify which big appliance turned on.

What this is

Layer What it does
collector Subscribes to the SlimmeLezer+ ESPHome native API (1 Hz) and stores every sample
detector Step-change detection → load episodes (on-step, duration, energy, peak)
api + UI Live power, event list, one-click labelling, CSV export for training
db TimescaleDB (Postgres 16) — 1-min continuous aggregate, compression after 7 days

No Home Assistant involvement on the ingest path (HA stays the notification shell).

Architecture decision (2026-10-04)

Separate service on dev CT141, not inside HAOS:

  • HA here is Core-in-Docker — custom Python services installed there die on every HA upgrade, and the recorder is not a dataset store (purges raw state ~10 days, writes on-change).
  • Ingest goes straight to the meter (192.168.178.213:6053, ESPHome API, no encryption) — no HA token, no secrets on this path.
  • Public URL via Coolify: loadwatch.xm2561.duckdns.org (the xm2561 apex belongs to Headscale — never take it).

Data model

samples(ts timestamptz, device text, key text, value double precision)  -- hypertable, 1 day chunks
events(id, ts_start, ts_end, direction, delta_w, peak_w, baseline_w, duration_s,
       energy_wh, appliance, label_source, labeled_at, notes)
appliances(name, notes, is_large)

samples is narrow (device, key) so additional sources — a smart plug, later a second meter — need no schema change.

Run it (dev)

cd /root/projects/loadwatch
cp .env.example .env         # set API_TOKEN
docker compose up -d --build
docker compose logs -f collector

UI: http://192.168.178.20:8099/ (token = API_TOKEN).

Collector entity keys

The collector matches ESPHome object_ids, discovered at connect time and logged:

object_id meaning
power_consumed_phase_1 instantaneous import W
power_produced_phase_1 instantaneous export W
voltage_phase_1, current_phase_1 grid V / A
energy_consumed_tariff_1/2 import kWh counters
energy_produced_tariff_1/2 export kWh counters
gas_consumed gas m³ (M-Bus, ~5 min)

If a key is missing the collector logs every object_id it can see — that is the discovery mechanism, not a guess.

Adding the smart plug (ground truth)

Add its host to METER_HOSTS (comma-separated) — samples land with device = <host>. A plug on one appliance gives labelled ground truth for exactly that appliance, which is what a supervised model needs; the P1 event stream covers everything else.

Export for training

GET /api/export.csv?days=30 → one row per labelled event plus its raw power window (GET /api/events/{id}/window returns the ±60 s raw trace for that event).

Detection defaults

EVENT_THRESHOLD_W=80 (step size), EVENT_MIN_DURATION_S=3, close back within 40 W held 3 s. Night baseload is ~50–200 W here; a kettle/oven/washer step is 1000–2500 W. Documented limitation: two loads stepping at the same instant inside one open episode are seen as one event.

Roadmap

  1. ✅ capture + detect + label (this repo)
  2. plug lane → labelled ground truth
  3. HA REST sensor → "big load started" notifications